  • The Tomey TL-6000 uses a 117 point Hartmann sensor wave front technology meaning superior measurement accuracy and speed for all types of lenses is guaranteed. Green LED measurement light allows measure of high index lenses without the need of ABBE compensation. With the TL-6000 you are able to show your patients the transmittance of blue light (465nm) and of UV light (375nm) passing through their lenses simultaneously while measuring the optical power. Lens mark recognition support means various grid patterns will assist you to recognise the lens marks easier as well as to visualise the distortion of multifocal lenses. The grid patterns are changed by swiping the finger over the 7" touch panel. The TL-6000 also allows you to visualise the progression zone of multifocal lenses with the simple power mapping function.

    TL-6000 Features:

    • Wave front technology with Hartmann sensor (117 points)
    • Simultaneous measurement of UV/blue light and power
    • Lens mark recognition support
    • Simple power mapping
    • LAN and RS-232C connection
  • EX-demo available

    The RT-7000 is a unique combination of topography, auto-refraction, keratometry and TSAS (tear stability analysis system) in one device. This multi-diagnostic instrument replaces four devices with all their functions. It is the perfect space and cost saving solution. Highly accurate measurements combined with short examination times and easy handling make working with the RT-7000 professional and quick. Alignment and measurement are done automatically - you just roughly align the system towards the patient's eye and the rest is taken care of by the instrument. The TSAS for analysing the tear film stability uses the light cone system and therefore offers you several measurement and analysis functions to detect patients with dry eye indication. For immediate understanding of the cornea topographic structure the RT-7000 implements the topographic indices KAI (Kerato-Asymetry Index) and KRI (Kerato-Regularity Index). These values are highlighted in colour (green = normal, yellow = suspect, red = abnormal) to provide you quick information about the corneal structure.

    RT-7000 Features:

    • 4 systems in 1 instrument
    • Colour touch screen
    • Different topography maps
    • Pupil & cornea measurement
    • Auto-alignment & auto-measurement
    • Tear stability analysis system (TSAS)
  • The TFC-1000 fully automatically generates a fundus image within 15 seconds using eye tracking and auto-focus as well as auto-measurement. The "KISS" (Keep It Short & Simple) principle had the highest priority in the software and workflow design. This makes the operation of the TFC-1000 extremely easy to handle. The user-friendly interface is very intuitive and provides the results in a very short time.

    TFC-1000 Features:

    • Automatic eye tracking
    • Non-mydriatic
    • Auto-focus & auto-measurement
    • Fundus image within 15 seconds
    • Multi-imaging display
    • Field of angle 45 x 45
    • 12 megapixel sensor
    • 9 fixation points
    • Anterior segment imaging
  • The TMS-4N guarantees high resolution with more than 60,000 data points. In addition the very short acquisition time (0.033 sec) assures you get the sharpest images for the highest accuracy. The TMS-4N has comprehensive software with single, dual and multiple map views allowing you to compare former data with new results. The Fourier analysis provides refractive information in 3mm and 6mm diameter range and also displays the spherical equivalent, regular astigmatism, asymmetry and higher order irregularity. Additional software applications such as Klyce statistics, keratoconus screening, enhanced height and height change maps are also available.

    TMS-4N Features:

    • Over 60,000 data points
    • Low light level cones
    • Auto-measurement & auto-select
    • Compatible software
    • Multilingual operation
    • Large patient database
    • Fourier refractive analysis
    • Keratoconus screening & other applications
  • iCare Tonometer probes (TP03) are packaged individually to ensure each patient has a safe and contamination free experience. To ensure reliable and accurate readings the probes should not be cleaned or re-used. It is recommended, to ensure patient safety and accuracy of IOP measurements, to only use original iCare probes only. The TP03 tonometer probes are for use in the iCare PRO Tonometer. Available from the only official UK distributor, Mainline Instruments.
  • iCare Tonometer probes (TA022P) are packaged individually to ensure each patient has a safe and contamination free experience. To ensure reliable and accurate readings the probes should not be cleaned or re-used. It is recommended, to ensure patient safety and accuracy of IOP measurements, to only use original iCare probes only. The TA022P tonometer probes are for use in the TA022 iCare HOME Tonometer. Available from the only official UK distributor, Mainline Instruments.
  • iCare IC100 tonometers for all eye care professionals. The iCare IC100 is based on a rebound measuring principle that requires no drop, airs or specialised skills for its use. The latest premium and innovative design and interface bring IOP measuring to a new level. Use iCare. Your patients will thank you for it.

    IC100 Features:

    • iCare AMS (Automatic Measuring Sequence) allows multiple readings or single reading with one button
    • Intuitive menu navigation interface
    • Intelligent positioning system for correct alignment of the tonometer
    The iCare IC100 is for UK sales only.
  • Using the Goldmann methodology for tonometry, the HT-5000 is Huvitz's applanation tonometer. It is mountable onto a variety of slit lamps and allows the user to determine approximate intraocular pressure.

    HT-5000 Features:

    • World standard Goldmann applanation tonometer
    • Digital display making it easy to read in dark environments
    • Wide grip dial for effortless adjustment of measuring prism
    • Optimised algorithm ensures the fast processing of IOP calculation
    • Instantaneous wake-up time from sleep mode
    • Powered by AAA batteries
    • Angled display matched to the angle of the user for comfortable observation
  • The Huvitz HRK-9000A combines everything into one simple device meaning patient workflow is improved by maximising efficiency.? It combines a auto-refractor keratometer, Contact Lens Fitting Guide (with colour camera), Meibomian Gland Analysis and Tear Film Break Up Time (TFBUT) functions in to a single instrument.  

    HRK-9000A Features

    • Subjective VA test
    • Wavefront technology
    • TFBUT measurement & Meibography
    • Wireless communication to other Huvitz products
    • Fully adjustable 7" touch colour display
    • Contrast sensitivity & glare test
    • Peripheral keratometry measurement
    • Auto-tracking feature
    • Colour View Mode: Full colour CCD camera and white LED source enables you to see eyes & contact lens fitting status previously only possible with slit lamps
    • Contact Lens Fitting Assistance Guide
    • Iris & Pupil diameter measurement
  • Huvitz Imaging System

    Enquire
    Enquire for Pricing
    Perfect solution to turn your HS-5000/5500 slit lamp into a complete image management system. Features:
    • A digital camera is attached to the binocular head where high resolution images can be captured and transferred to a pc.
    • Still images or videos are recorded using the joystick control on the base of the slit lamp.
    • Once the images are captured, they can easily be selected, manipulated and magnified to help you give an accurate diagnosis.
    • An MS Access Database allows you to search for symptoms, diagnosis information and record a patient's history, all within a user friendly environment.
    Camera and software included, please note that slit lamp must be bought separately.
  • The HS-7000 series is Huvitz's premium range of slit lamps:
    • With the global standard Galilean converging binocular type optic system, the Huvitz HS-7000 offers a wider angle, live image, and increased accuracy.
    • The five-position drum-style magnification changer provides a wide range of magnification from 6x to 40x
    • A yellow filter is conveniently located near the ocular for effortless insertion of the fluorescein pattern. With a control lever, any filters are easily inserted. Options included cobalt blue, red-free, heat absorption, grey and yellow.
    • The 12v, 30w high luminance halogen lamp provides incredible clarity for both image and video.
    There are two available models in the HS-7000 series. The HS-7000 is a Haag-Streit style slit lamp and the HS-7500 is a Zeiss style slit lamp.
  • A revolutionary design from Huvitz:
    • Zeiss style slit lamp offering cutting edge optical technology - favoured by many optometrists throughout the UK.
    • 30 watt, 12 volt high luminance halogen lamp - providing unbeatable clarity of images.
    • Galilean converging binocular optical system - offering a wide field of view with proven accuracy and reliability.
    • For ease of use, the yellow filter is conveniently placed near to the ocular for effortless display of the fluorescein pattern.
    • Any filters are easily inserted using a control lever (filter options include cobalt blue, heat absorption, red free, yellow and grey).
    • The HS-5500 has a five position drum style magnification chamber, offering a wide range of magnification settings from 6x to 40x.
    • If you are looking for a complete system, the HS-5500 can be combined with the HIS-5000 to produce a user friendly image management system.
    • A digital camera can be attached to the binocular head where high resolution images can be captured and transferred to a PC.
    • Still images or videos are recorded using the joystick control on the base of the slit lamp.
    • Once displayed on the PC, an MS Access Database allows you to search for symptoms, diagnosed information and a patient's history.
    • The images can then be manipulated within an intuitive, user friendly environment.